66.3 Debugging and Diagnostics Parameters
This subsection describes the device's debugging and diagnostic parameters.
66.3.1 General Parameters
The general debugging and diagnostic parameters are described in the table below.
General Debugging and Diagnostic Parameters
Parameter Description
CLI: enablesecsyslog
[EnableSecSyslog]
Enables the reporting of security-related events for the data-router
networking. When enabled, the data-router access list rules, configured
using the access-list CLI command, which are set to "log", send Syslog
messages whenever traffic matching the access list is encountered.
ï‚§ [0] = (Default) Disabled
ï‚§ [1] = Enabled
EMS: Enable Diagnostics
[EnableDiagnostics]
Determines the method for verifying correct functioning of the different
hardware components on the device. On completion of the check and if
the test fails, the device sends information on the test results of each
hardware component to the Syslog server.
ï‚§ [0] = (Default) Rapid and Enhanced self-test mode.
ï‚§ [1] = Detailed self-test mode (full test of DSPs, PCM, Switch, LAN,
PHY and Flash).
ï‚§ [2] = A quicker version of the Detailed self-test mode (full test of
DSPs, PCM, Switch, LAN, PHY, but partial test of Flash).
Note: For this parameter to take effect, a device reset is required.
Web: Enable LAN
Watchdog
[EnableLanWatchDog]
Enables the LAN watchdog feature.
ï‚§ [0] Disable (default)
ï‚§ [1] Enable
When LAN watchdog is enabled, the device's overall communication
integrity is checked periodically. If no communication is detected for
about three minutes, the device performs a self test:
ï‚§ If the self-test succeeds, the problem is a logical link down (i.e.,
Ethernet cable disconnected on the switch side) and the Busy Out
mechanism is activated if enabled (i.e., the parameter
EnableBusyOut is set to 1).
ï‚§ If the self-test fails, the device restarts to overcome internal fatal
communication error.
Notes:
ï‚§ For this parameter to take effect, a device reset is required.
ï‚§ Enable LAN watchdog is relevant only if the Ethernet connection is
full duplex.
[LifeLineType]
Defines the condition(s) upon which the Lifeline analog (FXS) feature is
activated. The Lifeline feature can be activated upon a power outage or
network failure (i.e., loss of IP connectivity). Upon any of these
conditions, the Lifeline feature provides PSTN connectivity and thus call
continuity for the FXS phone users.
If the device is in Lifeline mode and the scenario that caused it to enter
Lifeline (e..g., power outage) no longer exists (e.g., power returns), the
device exists Lifeline and operates as normal.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Media 800 MSBR and is the answer not in the manual?

AudioCodes Media 800 MSBR Specifications

General IconGeneral
BrandAudioCodes
ModelMedia 800 MSBR
CategoryNetwork Router
LanguageEnglish

Related product manuals