Version 5.8 305 October 2009
SIP User's Manual 6. Configuration Parameters Reference
6.3.2 Syslog, CDR and Debug Parameters
The Syslog, CDR and debug parameters are described in the table below.
Table 6-12: Syslog, CDR and Debug Parameters
Parameter Description
Web/EMS: Syslog Server
IP Address
[SyslogServerIP]
IP address (in dotted-decimal notation) of the computer you are using to
run the Syslog server. The Syslog server is an application designed to
collect the logs and error messages generated by the device.
Default IP address is 0.0.0.0.
For information on Syslog, refer to the Product Reference Manual.
Web: Syslog Server Port
EMS: Syslog Server Port
Number
[SyslogServerPort]
Defines the UDP port of the Syslog server.
The valid range is 0 to 65,535. The default port is 514.
For information on the Syslog, refer to the Product Reference Manual.
Web: Enable Syslog
EMS: Syslog enable
[EnableSyslog]
Sends the logs and error message generated by the device to the Syslog
server.
 [0] Disable = Logs and errors are not sent to the Syslog server
(default).
 [1] Enable = Enables the Syslog server.
Notes:
 For this parameter to take effect, a device reset is required.
 If you enable Syslog, you must enter an IP address and a port
number (using SyslogServerIP and SyslogServerPort parameters).
 You can configure the device to send Syslog messages implementing
Debug Recording, by using the SyslogOutputMethod ini file
parameter (for a detailed description on Debug Recording, refer to the
Product Reference Manual).
 Syslog messages may increase the network traffic.
 To configure Syslog logging levels, use the parameter
GwDebugLevel.
 For information on the Syslog, refer to the Product Reference Manual.
 Logs are also sent to the RS-232 serial port. For information on
establishing a serial communications link with the device, refer to the
device's Installation Manual.
[SyslogOutputMethod]
Determines the method used for Syslog messages.
 [0] = Send all Syslog messages to the defined Syslog server
(default).
 [1] = Send all Syslog messages using the Debug Recording
mechanism.
 [2] = Send only Error and Warning level Syslog messages using the
Debug Recording mechanism.
For a detailed description on Debug Recording, refer to the Product
Reference Manual.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes mediapack MP-500 and is the answer not in the manual?

AudioCodes mediapack MP-500 Specifications

General IconGeneral
BrandAudioCodes
Modelmediapack MP-500
CategoryGateway
LanguageEnglish

Related product manuals