161 HD96-24-CC-TP User Manual
Dual De-Esser
De-essing is an audio eect designed to reduce the amount of excessive sibilance in an audio signal, usually when dealing with the human voice. The Dual De-Esser
accurately and seamlessly removes sibilance from audio tracks.
The Lo-Band (around 6k for male or 7k female voices) and Hi-Band (around 11k) controls select which portion of the audio spectrum is aected by the De-Esser on each
channel. By increasing the amount of reduction, the level to which the de-essing aects the input signal can be controlled.
Item Control Function
1 Input Metering Metering shows input level.
2 Low GR - Meter Shows the amount of Low band S reduction. 0 to -14 dB.
3 Low GR threshold - Control Threshold controls the point at which the Low band begins responding to signal level.
4 Low GR threshold - Meter Displays the amount of gain reduction to be applied for the Low band.
5 Power - Switch Bypass the eect.
6 Low Band On - Switch Low Band active when illuminated.
7 Low Band Range - Switch Frequency select for the Low Band de-essing. 6k or 7k.
8 High Band On - Switch High Band active when illuminated.
9 High GR threshold - Control Threshold controls the point at which the High band begins responding to signal level.
10 High GR Level - Meter Displays the amount of gain reduction to be applied for the High band.
11 Low GR - Meter Shows the amount of Low band S reduction. 0 to -14 dB.
12 Output Metering Metering shows output level.