EasyManuals Logo
Home>Texas Instruments>Calculator>Voyage 200

Texas Instruments Voyage 200 User Manual

Texas Instruments Voyage 200
1008 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #824 background imageLoading...
Page #824 background image
826 Appendix A: Functions and Instructions
getTmZn() CATALOG
getTmZn()
integer
Returns an integer representing the time zone
that is currently set on the device.
The returned integer represents the number of
minutes the time zone is offset from Greenwich
Mean Time (GMT), as established in Greenwich,
England. For example, if the time zone is offset
from GMT by two hours, the device would return
120 (minutes).
Integers for time zones west of GMT are negative.
Integers for time zones east of GMT are positive.
If Greenwich Mean Time is 14:07:07, it is:
8:07:07 a.m. in Denver, Colorado (Mountain
Daylight Time) (–360 minutes from GMT)
16:07:07 p.m. in Brussels, Belgium (Central
European Standard Time)
(+120 minutes from GMT)
getType() CATALOG
getType(
var
)
string
Returns a string indicating the data type of
variable
var
.
If
var
has not been defined, returns the string
"
NONE".
{1,2,3}! temp ¸ {1 2 3}
getType(temp)
¸ "LIST"
2+3
i
! temp ¸ 2 + 3
i
getType(temp) ¸ "EXPR"
DelVar temp
¸ Done
getType(temp)
¸ "NONE"
Data Type Variable Contents
"ASM" Assembly-language program
"DATA" Data type
"EXPR" Expression (includes complex/arbitrary/undefined, ˆ, ë ˆ, TRUE, FALSE, pi,
e
)
"FUNC" Function
"GDB" Graph data base
"LIST" List
"MAT" Matrix
"NONE" Variable does not exist
"NUM" Real number
"OTHER" Miscellaneous data type for future use by software applications
"PIC" Picture
"PRGM" Program
"STR" String
"TEXT" Text type
"VAR" Name of another variable
getUnits() CATALOG
getUnits()
list
Returns a list of strings that contain the current
default units for all categories except constants,
temperature, amount of substance, luminous
intensity, and acceleration.
list
has the form:
{"
system
" "
cat1
" "
unit1
" "
cat2
" "
unit2
" …}
The first string gives the system (
SI, ENG/US, or
CUSTOM). Subsequent pairs of strings give a
category (such as Length) and its default unit
(such as _m for meters).
To set the default units, use
setUnits().
getUnits() ¸
{"SI" "Area" "NONE"
"Capacitance" "_F"
"Charge" "_coul"
}
Note: Your screen may display different default units.

Table of Contents

Other manuals for Texas Instruments Voyage 200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments Voyage 200 and is the answer not in the manual?

Texas Instruments Voyage 200 Specifications

General IconGeneral
TypeScientific
Form factorPocket
Product colorBlue
Display resolution128 x 240 pixels

Related product manuals