Configuring RIP RIP Options
OmniSwitch AOS Release 8 Network Configuration Guide December 2017 page 19-9
Configuring the RIP Interface Route Tag
Use the ip rip route-tag command to configure a route tag value for routes generated by the RIP
interface. This value is used to set priorities for RIP routing. Enter the command and the route tag value.
For example, to set a route tag value of 1 you would enter:
-> ip rip route-tag 1
The valid route tag value range is 1 to 2147483647.
Use the show ip rip command to display the current route tag value.
RIP Options
The following sections detail procedures for configuring RIP options. RIP must be loaded and enabled on
the switch before you can configure any of the RIP configuration options.
Configuring the RIP Forced Hold-Down Interval
The RIP forced hold-down timer value defines an amount of time, in seconds, during which routing
information regarding better paths is suppressed. A route enters into a forced hold-down state when an
update packet is received that indicates the route is unreachable and when this timer is set to a non-zero
value. After this timer has expired and if the value is less that 120 seconds, the route enters a hold-down
state for the rest of the period until the remainder of the 120 seconds has also expired. During this time the
switch accepts any advertisements for better paths that are received.
Note that the RIP forced hold-down timer is not the same as the RIP hold-down timer. The forced hold-
down timer defines a separate interval that overlaps the hold-down state. During the forced hold-down
timer interval, the switch does not accept better routes from other gateways. For more information on RIP
hold-down timer, see “Configuring the RIP Hold-Down Timer” on page 19-10.
Use the ip rip force-holddowntimer command to configure the interval during which a RIP route
remains in a forced hold-down state. Enter the command and the forced hold-down interval value, in
seconds. For example, to set a forced hold-down interval value of 10 seconds you would enter:
-> ip rip force-holddowntimer 10
The valid forced hold-down timer range is 0 to 120.
Use the show ip rip command to display the current forced hold-down timer value.
Configuring the RIP Update Interval
The RIP update interval defines the time interval, in seconds, when routing updates are sent out. This
interval value must be less than or equal to one-third the value of the invalid timer.
Use the ip rip update-interval command to configure the interval during which a RIP route remains in an
update state. Enter the command and the update interval value, in seconds. For example, to set an update
interval value of 45 seconds, you would enter:
-> ip rip update-interval 45
The valid update interval range is 1 to 120.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniSwitch 6860 Series and is the answer not in the manual?

Alcatel-Lucent OmniSwitch 6860 Series Specifications

General IconGeneral
BrandAlcatel-Lucent
ModelOmniSwitch 6860 Series
CategorySwitch
LanguageEnglish

Related product manuals