Configuring RIP RIP Options
OmniSwitch AOS Release 8 Network Configuration Guide December 2017 page 19-10
Configuring the RIP Invalid Timer
The RIP invalid timer value defines the time interval, in seconds, during which a route remains active in
the Routing Information Base (RIB) before it is moved to the invalid state. This timer value must be at
least three times the update interval value.
Use the ip rip invalid-timer command to configure the time interval that must elapse before an active
route becomes invalid. Enter the command and the invalid timer value, in seconds. For example, to set an
invalid interval value of 270 seconds you would enter:
-> ip rip invalid-timer 270
The invalid timer range is 3 to 360.
Configuring the RIP Garbage Timer
The RIP garbage timer defines the time interval, in seconds, that must elapse before an expired route is
removed from the RIB.
Note that during the garbage interval, the router advertises the route with a metric of INFINITY.
Use the ip rip garbage-timer command to configure the time interval after which an expired route is
removed from the RIB. Enter the command and the garbage timer value, in seconds. For example, to set a
garbage timer value of 180 seconds you would enter:
-> ip rip garbage-timer 180
The garbage timer range is 0 to 180.
Configuring the RIP Hold-Down Timer
The RIP hold-down timer defines the time interval, in seconds, during which a route remains in the
holddown state.
Whenever RIP detects a route with a higher metric than the route in the RIB, the route with the higher
metric goes into the hold-down state. The route updates with a metric of INFINITY are excluded.
Use the ip rip holddown-timer command to configure the interval during which a RIP route remains in
the hold-down state. Enter the command and the hold-down timer value, in seconds. For example, to set a
hold-down timer value of 10 seconds you would enter:
-> ip rip holddown-timer 10
The hold-down timer range is 0 to 120.
Reducing the Frequency of RIP Routing Updates
To optimize system performance, you can reduce the frequency of the RIP routing updates by increasing
the length of the update, invalid, and garbage timers by about 50% above their default values. For
example:
-> ip rip update-interval 45
-> ip rip invalid-timer 270
-> ip rip garbage-timer 180

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniSwitch 6860 Series and is the answer not in the manual?

Alcatel-Lucent OmniSwitch 6860 Series Specifications

General IconGeneral
BrandAlcatel-Lucent
ModelOmniSwitch 6860 Series
CategorySwitch
LanguageEnglish

Related product manuals