EasyManuals Logo

Alcatel-Lucent OmniSwitch 6860 Series User Manual

Alcatel-Lucent OmniSwitch 6860 Series
1078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
Configuring Ethernet Ports Interfaces Violation Recovery
OmniSwitch AOS Release 8 Network Configuration Guide December 2017 page 1-17
Configuring Interface Violation Recovery
The following sections provide information about how to configure parameter values that apply to the
interfaces violation recovery mechanisms.
Configuring the Violation Recovery Time
The violation recovery time specifies the amount of time the switch waits before automatically recovering
a port that was shut down due to a violation. When the recovery timer expires, the interface is
operationally re-enabled and the violation on the interface is cleared.
Consider the following when configuring the violation recover time:
The timer value does not apply to interfaces that are in a permanent shutdown state. A port in this state
is only recoverable using the interfaces split-mode command.
The interface violation recovery mechanism is not supported on link aggregates, but is supported on
the link aggregate member ports.
The violation recovery-time command is used to configure the automatic recovery time value, which is
configurable on a per-port or global basis. For example, the following commands set the violation
recovery time to 600 seconds at the global level and to 200 seconds for port 2/1 on chassis 1:
-> violation recovery-time 600
-> violation 1/2/1 recovery-time 200
The violation recovery time value configured for a specific interface overrides the global value configured
for all switch interfaces. To set the port-level value back to the global value, use the default parameter
with the violation recovery-time command. For example, the following command sets the violation
recovery time for port 2/1 on chassis 1 back to the global value of 600:
-> violation 1/2/1 recovery-time default
To disable the violation recovery timer mechanism, set the recovery time to zero. For example:
-> violation recovery-time 0
-> violation 1/2/1 recovery-time 0
Configuring the Violation Recovery Maximum Attempts
The violation recovery maximum setting specifies the maximum number of recovery attempts allowed
before a port is permanently shut down. This value increments by one whenever an interface recovers
from a violation using the automatic recovery timer mechanism. When the number of recovery attempts
exceeds this configured threshold, the interface is permanently shut down. The only way to recover a
permanently shut down interface is to use the interfaces split-mode command.
The recovery mechanism tracks the number of recoveries within a fixed time window (FTW). The FTW =
2 * maximum recovery number * recovery timer. For example, if the maximum number of recovery
attempts is set to 4 and the recovery timer is set to 5, the FTW is 40 seconds (2 * 4 * 5=40).
The show interfaces command is used to configure the maximum number of recovery attempts. This
value is configurable on a per-port or global basis. For example, the following commands set the number
of attempts to 3 at the global level and to 5 for port 2/1on chassis 1:
-> violation recovery-maximum 3
-> violation 1/2/1 recovery-maximum 5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniSwitch 6860 Series and is the answer not in the manual?

Alcatel-Lucent OmniSwitch 6860 Series Specifications

General IconGeneral
BrandAlcatel-Lucent
ModelOmniSwitch 6860 Series
CategorySwitch
LanguageEnglish

Related product manuals