Configuring Application Monitoring and Enforcement Configuring AppMon
OmniSwitch AOS Release 8 Network Configuration Guide December 2017 page 29-18
Configuring Logging Threshold
To configure the threshold value for the number of matched flows for enforcement and monitor
applications, use the app-mon logging-threshold command.
The maximum number of flows to be logged is in the range of 1000–60000 flows. When the logging
threshold value is set to ‘0’, flows are not logged to the log file.
When used with the monitor option, the threshold is configured for the number of matched flows to be
displayed in the monitor flow table commands. For example, the following command configures a
threshold value of 10000 for monitor applications.
-> app-mon logging-threshold monitor num-of-flows 10000
When used with the enforcement option, the threshold is configured for the number of matched flows to
be saved on to the log file for enforcement applications. For example, the following command configures
a threshold value of 30000 for enforcement applications.
-> app-mon logging-threshold enforcement num-of-flows 30000
To configure the default logging threshold, 20000, use the default keyword as shown.
-> app-mon logging-threshold monitor num-of-flows default
Configuring Sync Interval
Configures the interval at which the enforcement flows information is refreshed. The range for the interval
is 10–3600 seconds. The interval can be configured only for the enforcement feature.
Use the app-mon flow-sync enforcement interval command to force the flow sync. For example:
-> app-mon flow-sync enforcement interval 10
To configure the default interval value, 60 seconds, use the default keyword as shown.
-> app-mon flow-sync enforcement interval default
Default flow-sync interval is 300 seconds for monitoring. This is not user configurable.
Configuring Force Flow Sync
To synchronize the flows learned in the data path in real time, use the app-mon force-flow-sync
command. By default, flow synchronization occurs every 5 minutes for monitor flows and 60 seconds for
enforcement flows.
For example:
-> app-mon force-flow-sync enforcement
-> app-mon force-flow-sync monitor

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniSwitch 6860 Series and is the answer not in the manual?

Alcatel-Lucent OmniSwitch 6860 Series Specifications

General IconGeneral
BrandAlcatel-Lucent
ModelOmniSwitch 6860 Series
CategorySwitch
LanguageEnglish

Related product manuals