g. In the second 'Proxy Address' field, enter the IP address and port of the device (in
the format x.x.x.x:port). This is the same port as defined in the 'SAS Local
UDP/TCP/TLS Port' field (see ''Configuring Common SAS Parameters'' on page
288).
h. From the 'Proxy Redundancy Mode' drop-down list, select 'Homing'.
Figure 8-44: Defining Proxy Servers for Gateway Application
i. Click Submit.
2. Disable the use of user=phone in the SIP URL:
a. Open the 'SIP General Parameters' page (Configuration tab > VoIP menu > SIP
Definitions submenu > General Parameters).
b. From the 'Use user=phone in SIP URL' drop-down list, select 'No'. This instructs
the Gateway application to not use user=phone in SIP URL and therefore,
REGISTER and INVITE messages use SIP URI. (By default, REGISTER
messages are sent with sip uri and INVITE messages with tel uri.)
Figure 8-45: Disabling user=phone in SIP URL
c. Click Submit.

Table of Contents

Other manuals for AudioCodes MediaPack MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-124 and is the answer not in the manual?

AudioCodes MediaPack MP-124 Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-124
CategoryGateway
LanguageEnglish

Related product manuals