SIP User's Manual 460 Document #: LTRT-65415
MediaPack Series
Parameter Description
EMS: Current Disconnect Duration
[CurrentDisconnectDuration]
The duration (in msec) of the current disconnect pulse.
The range is 200 to 1500. The default is 900.
Notes:
 This parameter is applicable for FXS and FXO
interfaces.
 The FXO interface detection window is 100 msec below
the parameter's value and 350 msec above the
parameter's value. For example, if this parameter is set
to 400 msec, then the detection window is 300 to 750
msec.
 For this parameter to take effect, a device reset is
required.
[CurrentDisconnectDefaultThreshold]
Determines the line voltage threshold at which a current
disconnect detection is considered.
The valid range is 0 to 20 Volts. The default value is 4
Volts.
Notes:
 This parameter is applicable only to FXO interfaces.
 For this parameter to take effect, a device reset is
required.
[TimeToSampleAnalogLineVoltage]
Determines the frequency at which the analog line voltage
is sampled (after offhook), for detection of the current
disconnect threshold.
The valid range is 100 to 2500 msec. The default value is
1000 msec.
Notes:
 This parameter is applicable only to FXO interfaces.
 For this parameter to take effect, a device reset is
required.

Table of Contents

Other manuals for AudioCodes MediaPack MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-124 and is the answer not in the manual?

AudioCodes MediaPack MP-124 Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-124
CategoryGateway
LanguageEnglish

Related product manuals