2. CNC Monitor Screen
2.3(II) Tool Offset (M system)
(Refer to "2.3 (I). Tool Offset (L system)" for Lathe system)
I - 89
To register data exceeding the
number of data pieces that can be
displayed on a screen, set the #
number only. New data can be
registered.
Set “11” in # ( ), then press the
[INPUT] key.
(3) Data change
1) Display the TOOL LIFE data screen for the group in which the tool whose data is to be changed is
registered.
2) Set the # number of the data to be changed and new data in given parenthesis pairs of the
setting
area, then press the [INPUT] key.
3) After setting, the # number is incremented by one and is set in setting area ( ).
4) To change data under # number not displayed on the screen, change the screen by using the
[NEXT] or [BACK] key or setting the number in setting area # ( ).
5) By changing a registered tool number to 0, the tool can be deleted.
(4) Deletion in group units
To delete all data in one group, select the TOOL LIFE data screen for the group to be deleted and
press the [SHIFT] key, [C.B CAN] then [INPUT].
2.3.3.4 Clear of All TOOL LIFE Data (HEAD, NEXT, GROUP LIST Screen Pag
e
1)
To clear all data, select the HEAD, NEXT, GROUP LIST screen and press [SHIFT] key, [C.B CAN], then
[INPUT].