IV - 160
Appendix 7. Explanation of Alarms
Appendix 7.12 Program Errors (P)
Appendix 7.12 Program Errors (P)
(Note) Program error messages are displayed in abbreviation on the screen.
P10 EXCS. AXIS. No.
Details
The number of axis addresses commanded in a block is exceeds the specifications.
Remedy
- Divide the alarm block command into two.
- Check the specifications.
P11 AXIS ADR. ERROR
Details
The axis address commanded by the program does not match any of the ones set by the
parameter.
Remedy
- Correct the axis names in the program.
P20 DIVISION ERROR
Details
The issued axis command cannot be divided by the command unit.
Remedy
- Correct the program.
P30 PARITY H
Details
The number of holes per character on the paper tape is even for EIA code and odd for ISO
code.
Remedy
- Check the paper tape.
- Check the tape puncher and tape reader.
P31 PARITY V
Details
The number of characters per block on the paper tape is odd.
Remedy
- Make the number of characters per block on the paper tape even.
- Set the parameter parity V selection OFF.
P32 ADDRESS. ERROR
Details
An address not listed in the specifications has been used.
Remedy
- Correct the program address.
- Correct the parameter settings.
- Check the specifications.
P33 FORMAT ERROR
Details
The command format in the program is not correct.
Remedy
- Correct the program.