5. Operation Panel Switches in Operation Mode
5.1 Rapid Traverse Override
II - 16
5. Operation Panel Switches in Operation Mode
5.1 Rapid Traverse Override
Use the RAPID TRAVERSE OVERRIDE switch to
override the rapid traverse feedrate in automatic or
manual operation.
RAPID TRAVERSE OVERRIDE is applicable to the
following:
Automatic operation: G00, G27, G28, G29, G30
Manual operation: Rapid traverse, return to
reference position,
incremental feed
(Note)
Set the "CUTTING FEED OVERRIDE" switch to 0
to set the raid traverse override value to 0%.
5.2 Cutting Feed Override
Use the CUTTING FEED OVERRIDE switch to override
the feedrate in automatic operation (G01, G02, or G03F
command) or the manual feedrate of jog feed in manual
operation in 10% units in the range of 0% to 300%.
CUTTING FEED OVERRIDE is also applicable to the dry
run rate in automatic operation.
(Note 1)
The dry run rate is the movement rate set by using the MANUAL FEEDRATE switch by
overriding the programmed feedrate in automatic operation.
(Note 2)
See Section 6.6 for feedrate override applied to manual feedrate.
5.3 Manual Feedrate
Use the MANUAL FEEDRATE switch to set the feedrate in jog feed mode during manual operation. The
feedrate can be selected among 31 steps from 0 to 14000.0 mm/min.
When the MANUAL OVERRIDE switch (interrupt switch) is turned on, the override value set by using the
CUTTING FEED OVERRIDE switch takes precedence over the value set by using the MANUAL
FEEDRATE switch.
Manual feedrate (mm/min)
0. 7.2 72 720 7200
1.0 10.0 100 1000 10000
1.4 14.0 140 1400 14000
2.0 20.0 200 2000
2.7 27.0 270 2700
3.7 37.0 370 3700
5.2 52.0 520 5200
MANUAL FEEDRATE
72.0
52.0
31.0
21.0
20.0
14.0
10.0
7.2
6.2
3.7
2.7
2.0
1.4
1.0
0
140.0
200.0
270.0
370.0
520.0
720.0
1000.0
1400.0
2000.0
2700.0
3700.0
5200.0
7200.0
10000.0
14000.0
100
25
100
50
1
%
RAPID TRAVERSE OVERRIDE
CUTTING FEED OVERRIDE
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
150