2. CNC Monitor Screen
2.3(II) Tool Offset (M system)
(Refer to "2.3 (I). Tool Offset (L system)" for Lathe system)
I - 72
2.3.1.1 Tool Offset Data Setting
(1)
For type I
To set tool offset data, set the offset memory number in # ( ) and offset data in DATA ( ), then
press the [INPUT] input key.
(2) For type II
To set tool offset data, set the offset memory number in # ( ) and offset data in the setting area
corresponding to LENG, WEAR, RADIUS and WEAR, then press the [INPUT] key.
(3) If the [INPUT] key is pressed after the offset memory number and tool offset data are set, the tool offset
data set in the offset memory number position is displayed, the offset memory number in the setting
area # ( ) is incremented by one, and the contents of DATA ( ) disappear. At the time, the cursor
moves to the right end of the same setting field as the input time.
(4) If tool offset data is set with an offset memory number not contained in the displayed offset memory
numbers, the screen changes to the screen corresponding to the setup offset memory number when
the [INPUT] key is first pressed. When the [INPUT] key is pressed again, the tool offset data set in the
offset memory number position is displayed.
(5) The offset memory number displayed in # ( ) can be consecutively incremented or decreased by
one by pressing the [↑] or [↓] key.
(6) To set the incremental mode, enter "I" in # ( ), then press the [INPUT] key.
In incremental mode, the set data is added to the data indicated in the display area. To cancel the
incremental mode, enter "A" in # ( ), then press the [INPUT] key; the absolute mode is set. (Refer to
"2.3.1.3 Tool Offset Data Setting Modes (Absolute and Incremental)".)
2.3.1.2 Tool Offset Data Clear
(1)
Clear in display screen units
20 sets of tool offset data (10 sets for type II) are displayed on one screen. To clear all displayed offset
data, press the [SHIFT] key, then press the [C.B CAN] and [INPUT] keys.