EasyManuals Logo

Komatsu PC390LCi-11 User Manual

Komatsu PC390LCi-11
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #286 background imageLoading...
Page #286 background image
(G): When the quick coupler is installed
REMARK
2
persons are required to measure the dimensions (6) and the Angle (5) of the “Bucket Identification
Point”.
The work equipment is lowered due to hydraulic drift when it is above the ground. Perform measuring
of “Bucket Identification Point” as making sure that the plumb (11) is vertical from time to time.
METHOD FOR INPUTTING BUCKET INFORMATION (TILT BUCKET)
Input the measured dimensions and angles.
Tap the inside of the white frame of dimension value to be input
again, and then the numeric keypad pops up. Input the numeric
value with it.
Measure the length dimension to mm unit, and angle to 0.1 °
unit.
You can input the numeric value within the range shown below.
Numeric value (1)
Min: 0.00001 m to Max: 19.99999 m
Numeric value (2)
Min: 0.00001 m to Max: 19.99999 m
Numeric value (3)
Min: 0.0001 m to Max: 5.9999 m
Numeric value (4)
Min: 0.0001 m to Max: 2.9999 m
Angle (5)
Min: 0.01 ° to Max: 179.99 °
Numeric value (6)
Min: 0.0001 m to Max: 5.9999 m
Check the input numeric value. If there is no problem, tap “Next” button.
If any numeric value or angle column is empty, even if “Next” button is pressed, it is invalid.
CONTROL BOX SETTING
7-170