If this caution lamp does not go out although starting switch is operated, ask your Komatsu distributor for in-
spection and maintenance.
CYLINDER FUNCTION ST
ATE CAUTION LAMP
Cylinder function state caution lamp displays the state that
stroke measuring function of cylinder has not been reset.
Stroke measuring function of boom cylinder, arm cylin-
der, and bucket cylinder has not been reset since the
starting switch was turned on.
The caution lamp lights up in yellow. (Action level is not dis-
played.)
This is the state that stroke measuring function of cylinder has
never been reset since the starting switch was turned on.
Cylinder stroke may be mistakenly recognized. Keep each cyl-
inder of boom cylinder, arm cylinder, and bucket cylinder at its stroke end for 2 seconds before operation.
If this caution lamp does not go out, ask your Komatsu distributor for an inspection and maintenance.