Version 7.0 105 Mediant 3000
User's Manual 8. CLI-Based Management
8.4.7 PSTN Commands
The commands under the PSTN directory allow you to perform various PSTN actions.
Table 8-8: PSTN CLI Command
Command Short
Format
Arguments Description
PstnLoopCommand
s
PS/PH/PLC <TrunkId>
<LoopCode>
<BChannel>
Activates a loopback on a specific trunk
and B-channel. For loopback on the
entire trunk, set BChannel=(-1).
The valid value options for LoopCode
include the following:
ï‚§ 0 = NO_LOOPS
ï‚§ 1 = REMOTE_LOOP (whole trunk
only)
ï‚§ 2 = LINE_PAYLOAD_LOOP (whole
trunk only not applicable to DS3,
Sonet/SDH)
ï‚§ 3 =
LOCAL_ALL_CHANNELS_LOOP
(whole trunk only - not applicable to
DS3 or Sonet/SDH)
PstnSendAlarm
PS/PH/PSA <TrunkId>
<AlarmSendCode>
Sends an alarm signal at the Tx
interface or on a specific Trunk ID. The
valid value options for AlarmSendCode
include the following:
ï‚§ 0 = NO_ALARMS (means stop
sending AIS)
ï‚§ 1 = AIS_ALARM
ï‚§ 2 = STOP_RAI_ALARM
ï‚§ 3 = SEND_RAI_ALARM
DeleteCasFile
PS/CAS/DC
F
<TableIndex> Deletes all the device's CAS files when
<TableIndex> is set to -1 (other options
are currently not supported).

Table of Contents

Other manuals for AudioCodes Mediant 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 3000 and is the answer not in the manual?

AudioCodes Mediant 3000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 3000
CategoryGateway
LanguageEnglish

Related product manuals