User's Manual 224 Document #: LTRT-89730
Mediant 3000
AMD Detection
Sensitivity
Performance
Success Rate for Live Calls Success Rate for Answering Machine
15 (Best for Live
Calls)
97% 46%
15.5.1 Configuring AMD
You can configure AMD for all calls using the global AMD parameters, or for specific calls
using IP Profiles. The procedure below describes how to configure AMD for all calls. For
configuring AMD for specific calls, use the AMD parameters in the IP Profile table (see
''Configuring IP Profiles'' on page 391). For Gateway calls, AMD can be configured per call
based on the called number or Trunk Group. This is achieved by configuring AMD for a
specific IP Profile and then assigning the IP Profile to a Trunk Group in the Inbound IP
Routing table (see Configuring IP-to-Trunk Group Routing Rules on page 505).
 To enable and configure AMD for all calls:
1. Open the IPMedia Settings page (Configuration tab > VoIP > Media > IPMedia
Settings):
Figure 15-8: Configuring AMD Parameters in the IPMedia Settings Page
2. From the 'IPMedia Detectors' drop-down list (EnableDSPIPMDetectors), select
Enable to enable AMD.
3. Select the AMD algorithm suite:
a. In the 'Answer Machine Detector Sensitivity Parameter Suit' field, select the
required Parameter Suite included in the installed AMD Sensitivity file.
b. In the 'Answer Machine Detector Sensitivity' field, enter the required detection
sensitivity level of the selected Parameter Suite.
4. Configure the answering machine beep detection:
a. In the 'Answer Machine Detector Beep Detection Timeout' field
(AMDBeepDetectionTimeout), enter the duration that the beep detector operates
from when detection is initiated.
b. In the 'Answer Machine Detector Beep Detection Sensitivity' field
(AMDBeepDetectionSensitivity), enter the AMD beep detection sensitivity level.
5. Click Submit, and then reset the device with a burn-to-flash for your settings to take
effect.
For a complete list of AMD-related parameters, see ''IP Media Parameters'' on page 1048.

Table of Contents

Other manuals for AudioCodes Mediant 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 3000 and is the answer not in the manual?

AudioCodes Mediant 3000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 3000
CategoryGateway
LanguageEnglish

Related product manuals