User's Manual 1052 Document #: LTRT-89730
Mediant 3000
Parameter Description
AMD mode
[AMDmode]
Global parameter that enables the device to disconnect the IP-to-Tel
call upon detection of an answering machine on the Tel side. You can
also configure this functionality per specific calls, using IP Profiles
(IpProfile_AmdMode). For a detailed description of the parameter and
for configuring this functionality in the IP Profile table, see ''Configuring
IP Profiles'' on page 391.
Note: If this functionality is configured for a specific IP Profile, the
settings of this global parameter is ignored for calls associated with the
IP Profile.
Energy Detector Parameters
Enable Energy Detector
[EnableEnergyDetector]
Enables the Energy Detector feature. This feature generates events
(notifications) when the signal received from the PSTN is higher or
lower than a user-defined threshold (defined by the
EnergyDetectorThreshold parameter).
ï‚§ [0] Disable (default)
ï‚§ [1] Enable
Energy Detector Quality
Factor
[EnergyDetectorQualityFact
or]
Defines the Energy Detector's sensitivity level.
The valid range is 0 to 10, where 0 is the lowest sensitivity and 10 the
highest sensitivity. The default is 4.
Energy Detector Threshold
[EnergyDetectorThreshold]
Defines the Energy Detector's threshold. A signal below or above this
threshold invokes an 'Above' or 'Below' event.
The threshold is calculated as follows:
Actual Threshold = -44 dBm + (EnergyDetectorThreshold * 6)
The valid value range is 0 to 7. The default is 3 (i.e., -26 dBm).
Pattern Detection Parameters
Note: For an overview on the pattern detector feature for TDM tunneling, see DSP Pattern Detector
on page 446.
Enable Pattern Detector
[EnablePatternDetector]
Enables the Pattern Detector (PD) feature.
ï‚§ [0] Disable (default)
ï‚§ [1] Enable
[PDPattern] Defines the patterns that can be detected by the Pattern Detector.
The valid range is 0 to 0xFF.
Note: For the parameter to take effect, a device reset is required.
[PDThreshold] Defines the number of consecutive patterns to trigger the pattern
detection event.
The valid range is 0 to 31. The default is 5.
Note: For the parameter to take effect, a device reset is required.
58.14 Services
58.14.1 SIP-based Media Recording Parameters
The SIP-based media recording parameters are described in the table below.

Table of Contents

Other manuals for AudioCodes Mediant 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 3000 and is the answer not in the manual?

AudioCodes Mediant 3000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 3000
CategoryGateway
LanguageEnglish

Related product manuals