Version 7.0 799 Mediant 3000
User's Manual 53. Syslog and Debug Recording
Table 53-4: Syslog Facility Levels
Numerical Value Facility Level
16 (default)
local use 0 (local0)
17
local use 1 (local1)
18
local use 2 (local2)
19
local use 3 (local3)
20
local use 4 (local4)
21
local use 5 (local5)
22
local use 6 (local6)
23
local use 7 (local7)
Syslog messages begin with a less-than ("<") character, followed by a number, which is
followed by a greater-than (">") character. This is optionally followed by a single ASCII
space. The number is known as the Priority and represents both the Facility level and the
Severity level. A Syslog message with Facility level 16 is shown below:
Facility: LOCAL0 - reserved for local use (16)
53.2.1.5 Syslog Fields for Answering Machine Detection (AMD)
The Syslog message can include information relating to the Answering Machine Detection
(AMD) feature. AMD is used to detect whether a human (including a fax machine), an
answering machine, silence, or answering machine beeps have answered the call on the
remote side.
AMDSignal this field can acquire one of the following values:
voice (V)
answer machine (A)
silence (S)
unknown (U)
AMDDecisionProbability probability (in %) success that correctly detects answering
type
Below is an example of such a Syslog message with AMD information:
CallMachine:EVENT_DETECTED_EV - AMDSignal = <type V/A/S/U>,
AMDDecisionProbability = <percentage> %
If there is no AMD detection, the AMDSignal field is shown empty (i.e. AMDSignal = ).
For more information on the AMD feature, see ''Answering Machine Detection (AMD)'' on
page 221.
53.2.1.6 SNMP Alarms in Syslog Messages
SNMP alerts are sent to the Syslog server using the following formats:
Raised Alarms: RAISE-ALARM: <Alarm Name>; Textual Description: <Textual
Description>; Severity <Alarm Severity>; Source <Alarm Source>; Unique ID: <Alarm
Unique ID >.
If additional information exists in the alarm, then these are also added: Additional
Info1:/ Additional Info2:/ Additional Info3

Table of Contents

Other manuals for AudioCodes Mediant 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 3000 and is the answer not in the manual?

AudioCodes Mediant 3000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 3000
CategoryGateway
LanguageEnglish

Related product manuals