User's Manual 28. SBC Overview
28.9.15 Interworking SIP To-Header Tags in Multiple SDP Answers
The device supports the interworking of SIP To-header tags in call forking responses (i.e.,
multiple SDP answers) between IP entities. The device can either use the same To-header
tag value for all SDP answers sent to the SIP entity, or send each SDP answer with its
original tag. Employing IP Profiles, you can configure this interworking feature per SIP
entity, using the IpProfile_SBCRemoteMultipleEarlyDialogs parameter (see ''Configuring IP
Profiles'' on page 391).
28.9.16 Interworking In-dialog SIP Contact and Record-Route Headers
The device supports the interworking of in-dialog, SIP Contact and Record-Route headers
between SIP entities. Employing IP Profiles, you can configure this interworking feature per
SIP entity, using the IpProfile_SBCRemoteRepresentationMode parameter (see
''Configuring IP Profiles'' on page 391).