T200 User's Manual SECTION 1: T200 OVERVIEW
PAGE 1-6
1.3 Environmental Specifications
T200 Electronics
Temperature for transport and storage: -25 °C to 70 °C
Operating temperature: 0 °C to 55 °C
Relative Humidity: 5 % to 95 %, non-condensing, 1 g/m
3
to 25 g/m
3
,
in accordance with EN50178 class 3k3
Elevation: 3300feet
Derate output 2% per 1000 feet above 3300 feet
Type of protection: Components must be installed into an enclosure.
The enclosure must provide at least IP54 per standard
EN60529 or equivalent.
Installed position: Vertical only.
Overvoltage protection class: Category 2 per standard VDE0110 / IEC664
Noise: Overall noise depends on the user installation and cabinet.
Noise from the electronic components is less than 55dBA.