j) Wiring Practices - Ducts, connection and junction boxes
All sharp edges, flash, burrs, rough surfaces, or threads, with which the insulation of the conductors may come in
contact, shall be removed from ducts and fittings. Where necessary, additional protection consisting of a flame-retardant,
oil-resistant insulating material shall be provided to protect conductor insulation.
Ducts and cable trays shall be rigidly supported and positioned at a sufficient distance from the moving parts and in such
a manner so as to minimise the possibility of damage or wear.
Cable trunking systems external to enclosures shall be rigidly supported and clear of all moving or contaminating
portions of the machine or equipment into which they are installed.