Mediant 2000 & TP-1610 & TP-260/UNI
3.2.3.2 Removing Blades
Follow the procedures below for removing the TP-1610 and its associated RTM blade.
¾ To remove the TP-1610 blade from the chassis, take these 3 steps:
1. Unfasten the screws on the plate of the blade.
2. Press the red ejector buttons on the two black ejector/injector latches on both ends
and wait for the hot-swap blue LED to light, indicating that the blade can be removed.
3. Pull on the two ejector/injector latches and ease out the blade from the slot.
¾ To remove the TP-1610 RTM from the chassis, take these 4 steps:
1. Remove the cables attached to the RTM.
2. Unfasten the screws on the brackets at both ends of the panel that secure the RTM to
the chassis.
3. Press the red ejector buttons on the two black ejector/injector latches on both ends.
4. Grasp the panel and ease the RTM blade out of the slot.
3.2.4 Cabling the TP-1610
The cabling for the TP-1610 is listed below:
îš„ Connect the E1/T1 trunk interfaces (refer to 'Connecting the E1/T1 Trunk Interfaces'
on page 35)
îš„ Install the Ethernet connection (refer to 'Installing the Ethernet Connection' on page
36)
îš„ Optionally, connect the TP-1610 RS-232 port to your PC (refer to 'Connecting the RS-
232 Port to a PC' on page 37)