E1 Series Servo Drive User Manual Troubleshooting And Maintenance
HIWIN MIKROSYSTEM CORP. 13-21
13.5.1 Regular inspection
The servo drive does not need to be inspected daily, but the items listed in table 13.5.1.1 must be
inspected every half year or annually.
Table13.5.1.1
Item Frequency Inspection Corrective Action
and
Half year or
annually
No litter, dust, oil and stain, etc.
Clean the environment and
the servo drive.
Screws
Parts must be tightened, such as
terminal block, connector and screw,
etc.
Tighten the parts with screw
driver.
13.5.2 Replacement standard
The electronic parts inside the servo drive are subject to mechanical wear or deterioration. Table 13.5.2.1
provides the replacement standards for the electronic parts.
Table13.5.2.1
Part Replacement Standard Note
Fan 4~5 years
Ambient temperature: average
30°C
Operation time: 20 hours/day
Electrolytic Capacitor 2 years
Relay Power on for 30,000 times. Frequency: 1 time/hour
Battery 2.5 years (No power is supplied.) Storage temperature: 20°C
When replacement standard is met, contact HIWIN or our distributors to check if replacement is required.