E1 Series Servo Drive User Manual Electrical Planning
HIWIN MIKROSYSTEM CORP. 5-35
5.6.2 Wiring for STO safety function
Ensure you have safety device connector (HIWIN part number: 051500400404) before wiring. For the
specification of the connector, please refer to section 16.2.3.
Wiring for STO safety function
Figure5.6.2.1
Wiring example of STO safety function
Figure5.6.2.2
+24VDC
4
SF1+
3
SF1-
5
SF2-
7
EDM-
6
SF2+
8
EDM+
Servo drive
Power module
Monitor
Cut off