7 CiA402 device profile
7.4 Device control
179
Lenze · i700 servo inverter · reference manual · DMS 3.0 EN · 06/2016 · TD06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.4 Device control
The objects described in this chapter serve to control the states of the servo inverter and to select
the operating mode.
All objects correspond to the CiA402 specification, but some of them have only a restricted value
range.
Objects described in this chapter:
0x6040 | 0x6840 - CiA402 controlword
0x6041 | 0x6841 - Statusword
Object Name Data type
Axis A Axis B
0x6040 0x6840 Controlword UNSIGNED_16
0x6041 0x6841 Statusword UNSIGNED_16
0x605A 0x685A Quick stop option code INTEGER_16
0x6060
0x6860 Operating mode: Selection INTEGER_8
0x6061 0x6861 Modes of operation display INTEGER_8
0x6085 0x6885 Quick stop deceleration UNSIGNED_32
Greyed out = read access only
Control word for the drive
Setting range (min. value | unit | max. value) Lenze setting
0 65535 0
Value is bit-coded: ( =bit set) Info
Bit 0 Switching on
Bit 1 DC bus: Establish readiness for
operation
Bit 2 Activate quick stop
Bit 3 Enable operation
Bits 4-6 Depending on the operating mode
Bit 7 Fault reset Indication of fault and warning (error code)
Bit 8 Not specified
Bit 9 Depending on the operating mode
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Release brake Holding brake control
Bit 15 Reserved
Write access CINH OSC P RX TX UNSIGNED_16
Status word from the drive

Table of Contents

Other manuals for Lenze i700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i700 and is the answer not in the manual?

Lenze i700 Specifications

General IconGeneral
Control TypeVector control, V/f control
SafetySTO (Safe Torque Off)
Protection ClassIP20
Frequency50/60 Hz
Communication InterfacesCANopen
CoolingAir cooled
Protection FeaturesOvervoltage, Undervoltage
Ambient Temperature-10°C to +45°C
Frequency Range0 Hz to 300 Hz
Supply Voltage3-phase AC

Related product manuals