Lenze · i700 servo inverter · reference manual · DMS 3.0 EN · 06/2016 · TD06 251
8 Monitoring functions
8.1 24-V supply voltage monitoring
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8 Monitoring functions
The i700 servo inverter is provided with various monitoring functions, which are described in the
following subchapters.
Objects described in this chapter
8.1 24-V supply voltage monitoring
The 24 V supply voltage is monitored by means of two specified voltage thresholds.
• The following table describes these thresholds and shows the device response resulting from
the level of the supply voltage:
Related topics:
Monitoring of the DC-bus voltage
( 49)
Object Name Data type
Axis A Axis B
0x2D40 0x3540 Ixt utilisation RECORD
0x2D44
0x3544 Motor speed monitoring RECORD
0x2D45
0x3545 Motor phase failure detection RECORD
0x2D46
0x3546 Monitoring: Ultimate motor current RECORD
0x2D49
0x3549 Motor temperature monitoring: Parameter RECORD
0x2D4C
0x354C Motor utilisation (I²xt): Parameter for the thermal model RECORD
0x2D4D
0x354D Motor utilisation (I²xt): User-definable characteristic RECORD
0x2D4E
0x354E Motor utilisation (I²xt): Motor overload warning threshold UNSIGNED_16
0x2D4F
0x354F Motor utilisation (I²xt): Actual utilisation UNSIGNED_16
0x2D50
0x3550 Motor utilisation (I²xt): Motor overload error UNSIGNED_32
0x2D84
0x3584 Heatsink temperature RECORD
Threshold Voltage Device response
U24 warn 21.45 V ±5 % Above threshold: Normal operation
Below threshold: Normal operation with warning
U24 down 18.15 V ±5 % Above threshold: Normal operation with warning
Below threshold: No operation
• Response with regard to the EtherCAT master and
adjacent EtherCAT slaves is undefined.