Lenze · i700 servo inverter · reference manual · DMS 3.0 EN · 06/2016 · TD06 20
2 Parameter handling
2.2 Storage parameter set (par001.*) and total parameter set (par000.*)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2.2 Storage parameter set (par001.*) and total parameter set (par000.*)
For the storage of the i700 servo inverter parameters, two different parameter sets are provided,
which are stored in different parameter set files in the higher-level controller:
Storage parameter set (par001.i7psf)
Only contains the parameters of the i700 servo inverter which are writable and identified with
the "P" attribute (persistent).
Parameters can be read out from the i700 servo inverter and saved to the file. Conversely, the
parameters stored can be written to the i700 servo inverter again.
Recommended for storage and archiving of the servo inverter settings.
Total parameter set (par000.i7psf)
Contains all parameters of the i700 servo inverter, including the mere display parameters which
vary permanently during operation.
The total parameter set can only be read from the i700 servo inverter.
Use for purposes of service and diagnostics.
The structure of the parameter set file is described in the appendix.
Structure of the parameter set file ( 332)