Lenze · i700 servo inverter · reference manual · DMS 3.0 EN · 06/2016 · TD06 20
2 Parameter handling
2.2 Storage parameter set (par001.*) and total parameter set (par000.*)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2.2 Storage parameter set (par001.*) and total parameter set (par000.*)
For the storage of the i700 servo inverter parameters, two different parameter sets are provided,
which are stored in different parameter set files in the higher-level controller:
Storage parameter set (par001.i7psf)
• Only contains the parameters of the i700 servo inverter which are writable and identified with
the "P" attribute (persistent).
• Parameters can be read out from the i700 servo inverter and saved to the file. Conversely, the
parameters stored can be written to the i700 servo inverter again.
• Recommended for storage and archiving of the servo inverter settings.
Total parameter set (par000.i7psf)
• Contains all parameters of the i700 servo inverter, including the mere display parameters which
vary permanently during operation.
• The total parameter set can only be read from the i700 servo inverter.
• Use for purposes of service and diagnostics.
The structure of the parameter set file is described in the appendix.
Structure of the parameter set file ( 332)