Lenze · i700 servo inverter · reference manual · DMS 3.0 EN · 06/2016 · TD06 204
7 CiA402 device profile
7.5 Parameters for the scaling of physical values
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x608F
is selected in such a way that the values to be parameterised only slightly exceed the display
option of the feedback system.
0x6090 | 0x6890 - Velocity encoder resolution
Note: This object is not used in the firmware and only available for compatibility reasons. Do not use the contained
values for a calculation on the control level.
Sub. Name Lenze setting Data type
1 Incr./s 33554432 UNSIGNED_32
2 Motor revolutions/s 125 UNSIGNED_32
Write access CINH OSC P RX TX