Spectrum Measurements
R&S
®
ESR
407User Manual 1175.7068.02 ─ 12
Tasks
"Basic Marker Functions" on page 408
Softkeys of the Marker Menu
Functions to control markers described elsewhere:
"Marker 1 / Marker 2 / Marker 3 / … Marker 16,/ Marker Norm/Delta" on page 201
"Marker to Trace" on page 202
"Marker Wizard" on page 202
"All Marker Off" on page 203
"Marker Table" on page 203
"Marker Info (On Off)" on page 203
Functions to control markers exclusive in Spectrum mode
Marker Stepsize.......................................................................................................... 407
Stepsize Standard.........................................................................................407
Stepsize Sweep Points................................................................................. 407
Marker Zoom (span > 0)..............................................................................................408
Link Mkr1 and Delta1.................................................................................................. 408
Marker Stepsize
Opens a submenu to set the step size of all markers and delta markers.
Default value for the marker step size is Stepsize Sweep Points.
Stepsize Standard ← Marker Stepsize
Moves the marker or delta marker from one measurement point to the next, if the
marker or delta marker value is changed via the rotary knob ( "Marker 1 / Marker 2 /
Marker 3 / … Marker 16,/ Marker Norm/Delta" softkeys, see "Marker 1 / Marker 2 /
Marker 3 / … Marker 16,/ Marker Norm/Delta" on page 201). If more measured values
than measurement points exist, it is not possible to read out all measured values. In
this case, use the Stepsize Sweep Points softkey.
Remote command:
CALC:MARK:X:SSIZ STAN (see CALCulate<n>:MARKer<m>:X:SSIZe
on page 864)
Stepsize Sweep Points ← Marker Stepsize
Moves the marker or delta marker from one measured value to the next, if the marker
or delta marker value is changed via the rotary knob ( "Marker 1 / Marker 2 / Marker 3 /
… Marker 16,/ Marker Norm/Delta" softkeys, see "Marker 1 / Marker 2 / Marker 3 / …
Marker 16,/ Marker Norm/Delta" on page 201). If more measured values than mea-
surement points exist, every single measured value is accessible and its value is dis-
played in the marker field.
The number of measured values is defined in the ""Sweep"" menu via the Sweep
Points softkey.
This functionality is not available for statistical measurements (APD and CCDF).