EasyManuals Logo

Siemens SINAMICS S120 User Manual

Siemens SINAMICS S120
826 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #297 background imageLoading...
Page #297 background image
Line Modules Booksize
4.10 Smart Line Modules with external air cooling
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
297
4.10.4.5
X24 24 V terminal adapter
Table 4- 80 X24: 24 V terminal adapter
Terminal
Designation
Technical data
+
24 V power supply
24 V DC supply voltage
M Ground Electronics ground
Type: Screw terminal 5 (Page 730)
The 24 V terminal adapter is included in the scope of supply.
4.10.4.6
X200-X202 DRIVE-CLiQ interfaces
Table 4- 81 X200-X202: DRIVE-CLiQ interfaces
PIN
Signal name
Technical data
1
TXP
Transmit data +
2
TXN
Transmit data -
3
RXP
Receive data +
4
Reserved, do not use
5
Reserved, do not use
6
RXN
Receive data -
7
Reserved, do not use
8
Reserved, do not use
A
+(24 V)
24 V power supply
B
M (0 V)
Electronics ground
The blanking covers for the DRIVE
-CLiQ interfaces are included in the scope of delivery.
Blanking cover (50 pcs.) Article number: 6SL3066-4CA00-0AA0

Table of Contents

Other manuals for Siemens SINAMICS S120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S120 and is the answer not in the manual?

Siemens SINAMICS S120 Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S120
CategoryDC Drives
LanguageEnglish

Related product manuals