Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
369
Table 6- 11 Technical data Single Motor Modules Booksize (3 to 30 A)
Rated current (l
n
)
Base-load current (I
H
)
Intermittent duty current (I
s6
) 40 %
max
A
AC
A
A
AC
AC
2.6
3.5
4.3
6
7.7
10
15.3
24
25.5
40
0 … 0.717 x DC-link voltage
d rated
DC
DC-link voltage (up to 2000 m above sea level)
Overvoltage trip
2)
V
DC
820 ± 2 %
DC
Electronics current drawn
at 24 VDC
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
A
DC
A
DC
DC
100
150
3)
Based on I
n
(600 VDC; 4 kHz)
H
kW
1.6
2.7
4.8
9.7
16
(including electronics losses, see Power loss
W 50.4 73.4 100.4 185.4 309.2
without derating
kHz
4
Hz 0 … 550
3
Max. permissible heat sink temperature
Applies only to Article numbers with "." = 0 ... 3
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the parame-
terized rated voltage
3)
Rated power of a typical standard induction motor at 400 V 3 AC.