Motor Modules Booksize
6.5 Motor Modules Liquid Cooled
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
453
For installation, M6 threaded bolts and hexagon nuts/grub screws to ISO 7436-M6x40-14 H,
property class 8.8 are recommended.
The coolant connections are located on the lower side of the components. All connection
elements can be accessed using an appropriate tool.
● Thread type for coolant connections: Pipe thread ISO 228 G ½ B.
Table 6- 52 Technical data for Motor Module Liquid Cooled 200 A
Rated current (I
n
)
Base-load current (I
H
)
Intermittent duty current (I
S6
) 40%
max
A
AC
A
A
AC
AC
200
141
230
d rated
DC
DC link voltage (up to 2000 m above sea level)
Overvoltage trip
1)
V
DC
820 ± 2 %
DC
Electronics current drawn
at 24 VDC
Current carrying capacity
DC-link busbars
A
DC
DC
200
2)
Based on I
n
(600 VDC; 4 kHz)
kW
107
(including electronics losses, see Power
loss tables (Page 756))
W 2070.4
without derating
kHz
4
Hz 0 … 550
without derating
° C
45
Max. permissible heat sink temperature
for water at 70 kPa pressure drop
(for other coolant (Page 771))
l/min 8
Volume of liquid internal