Motor Modules Booksize
6.3 Motor Module with external air cooling
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
405
kg 13.2 13.3 17.2 27.1 28
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V (exception: 132 A and 200 A
Motor Modules) and is adjusted to the parameterized rated voltage.
2)
Rated power of a typical standard induction motor at 400 V 3 AC.
Table 6- 29 Technical data, Double Motor Modules Booksize (2 x 3 to 2 x 18 A)
Rated current (l
n
)
Base-load current (I
H
)
Intermittent duty current (I
s6
) 40 %
A
AC
A
A
AC
2 x 2.6
2 x 3.5
2 x 4.3
2 x 6
2 x 7.7
2 x 10
2 x 15.3
2 x 24
AC
DC
Overvoltage trip
2)
V
DC
DC
820 ± 2 %
Electronics current drawn
at 24 VDC
DC
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
A
DC
A
DC
100
150
100
150
100
150
100
150
3)
Based on I
n
(600 VDC; 4 kHz)
kW
2 x 1.6
2 x 2.7
2 x 4.8
2 x 9.7
(including electronics losses, see Power loss
W 97.6 132.6 187.6 351.2
without derating
kHz
4
3
Max. permissible heat sink temperature