Motor Modules Booksize
6.4 Motor Modules with cold plate
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
435
Note
New systems with 132
A and 200 A Motor Modules should ideally be designed with 200 A
liquid
-cooled Motor Modules in order to avoid current derating.
6.4.7.2
Double Motor Modules
Table 6- 44 Technical data Double Motor Modules (2 x 3 to 2 x 18 A)
Cold plate
6SL3126-
2TE13-0AA.
1)
2TE15-0AA.
1)
2TE21-0AA.
1)
2TE21-8AA.
Output current
Rated current (I
n
)
Base-load current (I
H
)
Intermittent duty current (I
S6
) 40%
Peak current (I
max
)
A
AC
A
A
AC
A
AC
2 x 3
2 x 2.6
2 x 3.5
2 x 6
2 x 5
2 x 4.3
2 x 6
2 x 10
2 x 9
2 x 7.7
2 x 10
2 x 18
2 x 18
2 x 15.3
2 x 24
2 x 36
Output voltage
V
AC
0 … 480
DC link current I
d rated
A
DC
7.2
12
22
43
DC-link voltage
V
DC
510 … 720
DC-link capacitance
μF
110
220
220
705
Overvoltage trip
Undervoltage trip
2)
V
DC
V
DC
820 ± 2 %
380 ± 2 %
Electronics power supply
V
DC
24 (20.4 … 28.8)
Electronics current drawn
at 24 VDC
A
DC
0.9
0.9
0.9
1.05
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
24 VDC busbars
A
DC
A
DC
A
DC
100
150
20
100
150
20
100
150
20
100
150
20
Unit rating
3)
Based on I
n
(600 VDC; 4 kHz)
Based on I
H
kW
kW
2 x 1.6
2 x 1.4
2 x 2.7
2 x 2.3
2 x 4.8
2 x 4.1
2 x 9.7
2 x 8.2
Total power loss
(including electronics losses, see Power
loss tables (Page 756))
W 91.6 126.6 181.6 345.2
Max. pulse frequency
without derating
with derating
kHz
kHz
4
16
Output frequency
Hz
0 … 550
Max. permissible heat sink temperature
° C
80
80
90
90
Ventilation clearances
above/below
mm
≥ 80
Weight
kg
4.5
4.5
4.5
5.9
1)
Applies only to Article numbers with "." = 0 ... 3
2)
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the parame-
terized rated voltage
3)
Rated power of a typical standard induction motor at 400 V 3 AC

Table of Contents

Other manuals for Siemens SINAMICS S120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S120 and is the answer not in the manual?

Siemens SINAMICS S120 Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S120
CategoryDC Drives
LanguageEnglish

Related product manuals