2-4
PERIODIC
MAINTENANCE
EXHAUST
PIPE
NUTS
AND
MUFFLER
BOLTS
Tighten initially
at 200 km (100
miles,
1
month)
and
every
1
000 km (600
miles,
3
months) thereafter.
•
Remove
the rear fender. (CU
3
7-7)
• Tighten the exhaust pipe nuts
©,
muffler connection bolt (2),
and muffler mounting bolts
®
to the specified torque.
H
Exhaust
pipe
nut: 23 Nm (2.3
kgf-m,
16.5 Ib-ft)
Muffler
connection bolt:
23 N m (2.3
kgf-m,
16.5 Ib-ft)
Muffler
mounting bolt:
23 N m (2.3
kgf-m,
16.5 Ib-ft)