Error Troubleshooting
Phaser 7100 Service Manual Xerox Internal Use Only2-284
(Y/ M/ C) Imaging Unit Error: Life End
The (Y/ M/ C) Imaging Unit Life End error has occurred due to one of the following problems.
• Imaging Unit (Y/ M/ C) Quality End of Life
• The Imaging Unit life end is detected.
Applicable Fault Codes
• 091-480: Imaging Unit Y Quality End of Life
• 091-481: Imaging Unit M Quality End of Life
• 091-482: Imaging Unit C Quality End of Life
• 091-932: Imaging Unit Y End Of Life
• 091-933: Imaging Unit M End Of Life
• 091-934: Imaging Unit C End Of Life
Initial Actions
• Check the Imaging Unit life. Access CWIS > Status > Consumables.
• If the problem persists, perform the following procedure.
Troubleshooting Reference
Applicable Parts Wiring and Plug/Jack Map References
• Imaging Unit (Y/ M/ C), PL 6.1.1
Troubleshooting Procedure
Step Actions and Questions
1. Replace the Imaging Unit (Y/ M/ C) (REP 6.0 Imaging Unit (Y/ M/ C/ K) on page 4-121).