Error Troubleshooting
Xerox Internal Use Only Phaser 7100 Service Manual 2-405
202-399 Timer Internal Fail
The System Data = 700-124 (Auto Clear Timer (Combining Auto Resume Timer, Auditron Off Timer
and Tools Off Timer)) settings value was detected to be from 1 to 29 in an MF device. This failure does
not occur in Prt machines for values of 1 to 29.
Applicable Fault Code
• 202-399: Timer Internal Error Detected by UI Cont
Initial Actions
• Power cycle the printer.
• If the problem persists, perform the following procedure
.
Troubleshooting Procedure
Step Actions and Questions
1. Check the System Data = 700-124 (Auto Clear Timer, Auto Resume Timer, Auditron Off Timer and
Tools Off Timer) value.
This failure will occur when values of 1 to 29 is set in the MF device.
• Other than 700-124, this failure may also occur when any timer-related System Data settings
value is changed. In that case, check the corresponding System Data for the correct value.
2. If the problem persists, go to Common System Fail on page 2-406.