368 Configuring Switching Information
NOTE: If an Access port is chosen, the packet types that are accepted on the port (packet type) cannot be
designated. It is also not possible to enable or disable ingress filtering on an access port.
3.
Use the
Unit
drop-down menu to view the
VLAN Port Table
for other units in the stack, if they exist.
Modifying Settings for Multiple Ports
1.
Open the
VLAN Port Settings
page.
2.
Click
Show All
.
The
VLAN Port Table
displays.
3.
Click
Edit
for each Port to modify.
4.
Edit fields as needed.
5.
Click
Apply Changes
.
The VLAN port settings are modified, and the device is updated.
Configuring VLAN Ports Using CLI Commands
For information about the CLI commands that perform this function, see the following chapter in the
CLI Reference Guide
:
VLAN Commands
The following table summarizes the equivalent CLI commands for this feature.
VLAN LAG Settings
Use the VLAN LAG Settings page to map a LAG to a VLAN. Untagged packets entering the switch are
tagged with the LAGs ID specified by the PVID.
To display the VLAN LAG Settings page, click Switching
VLAN
LAG Settings in the tree view.
Table 7-28. VLAN Port Configuration Commands
CLI Command Description
switchport access vlan Configures the VLAN ID when the interface is in access mode.
switchport general acceptable-frame-type
tagged-only
Discards untagged frames at ingress.
switchport general ingress-filtering disable Disables port ingress filtering.
switchport general pvid Configures the PVID when the interface is in general mode.
switchport mode Configures the VLAN membership mode of a port.

Table of Contents

Other manuals for Dell PowerConnect 6224

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 6224 and is the answer not in the manual?

Dell PowerConnect 6224 Specifications

General IconGeneral
Switching Capacity128 Gbps
Forwarding Rate95.2 Mpps
Power Supply100-240 VAC, 50/60 Hz
RAM128 MB
Flash Memory32 MB
Layer SupportLayer 2/3
StackingUp to 12 units
Weight12.1 lbs
MAC Address Table Size16, 000
Jumbo Frame SupportUp to 9, 216 bytes
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Humidity10% to 90% (non-condensing)
Ports24 x 10/100/1000BASE-T
VLAN SupportYes (802.1Q)
Dimensions17.3 x 13.8 x 1.7 in (440 x 350 x 44 mm)