Phaser 7500 Printer Service Manual 3-241
Error Messages and Codes
RC Data Over Range Fail
The result from adding the offset value to the correction value has exceeded the
settable range.
Applicable Chain-Link Code
• 089-617: RC Data Over Range Fail
Initial Actions
• Power cycle the printer.
• If the problem persists, follow the procedure below.
When multiple failures with Chain No. 089 occur, take action according to the
priority order.
1. Perform NVRAM Read/Write test in Diagnostics.
2. Check that the value is "0". (Because this error occurs only when the NVM write
data is incorrect or the NVM is corrupted, if the setting value is not "0", reset it
to "0".)
Troubleshooting Reference
Applicable Parts Wiring and Plug/Jack Map References
â– LPH Unit (Y, M, C, K), PL2.1.2