Issue 2.0
5-22 SV9100 IP K-CCIS
2.2 VoIP IP Address Assignments
For this feature, the GPZ-IPLE, daughter board is installed on the GCD-CP10
blade. The GPZ-IPLE daughter board reduces the maximum capacity of trunks in
the system.
22-02-01
Incoming Call Trunk
Setup – Trunk Type
001 ~ 400
0 = Normal
1 = VRS (second dial tone if no
VRS installed)
2 = DISA
3 = DID
4 = DIL
5 = E&M Tie line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID(DDI) Mode
Switching
Default is 0
Set the feature type for
the trunk you are
programming.
Table 5-8 VoIP IP Address Assignments
Program/
Item No.
Description/Selection Assigned Data Comments
84-26-01
IPL Basic Setup – IP
Address
XXX.XXX.XXX.XXX Assign the VOIPDB Gateway IP
Address.
Slot 1 = 172.16.0.20
84-26-02
IPL Basic Setup – RTP
Port Number
0~65534 Default:
RTP Port = 10020
84-26-03
IPL Basic Setup – RTCP
Port Number
(RTP Port Number + 1)
0~65534 Default:
RTCP = 10021
Table 5-7 Digital Trunk Assignments (Continued)
Program/
Item No.
Description/Selection Assigned Data Comments

Table of Contents

Other manuals for NEC Univerge SV9100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Univerge SV9100 and is the answer not in the manual?

NEC Univerge SV9100 Specifications

General IconGeneral
VoIP SupportYes
VoIP ProtocolsSIP, H.323
VoicemailIntegrated voicemail
NetworkingYes, via IP
Unified CommunicationsYes
MobilitySupports mobile extensions and applications
TypeIP-PBX
Network InterfacesGigabit Ethernet
Power SupplyAC 100-240V, 50/60Hz
Operating Temperature32°F to 104°F (0°C to 40°C)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
WeightVaries depending on chassis and expansion cards

Related product manuals