Issue 2.0
2-8 IP Networking
4.2.7 Centralized Day Night Switching Assignments
Use the table below to make the appropriate assignments for centralized
day and night switching.
System A System B
PRG 50-06-02 CCIS Feature
Availability - Centralized Day/Night
Switching
0 = Disable (default)
1 = Enable
PRG 50-06-02 CCIS Feature
Availability - Centralized Day/Night
Switching
0 = Disable (default)
1 = Enable
PRG 50-11-02 CCIS Centralized Day/
Night Switching Sending Group
Assignment - CCIS Route ID
Send Group (1~8)
CCIS Route ID
0 = No Setting (default)
1~4
PRG 50-11-02 CCIS Centralized Day/
Night Switching Sending Group
Assignment - CCIS Route ID
Send Group (1~8)
CCIS Route ID
0 = No Setting (default)
1~4
PRG 50-12-01 CCIS Centralized Day/
Night Mode to System Mode
Assignment - Day Mode
Day Mode = Mode 1~8
1 = default
Night Mode = Mode 1~8
2 = default
PRG 50-12-01 CCIS Centralized Day/Night
Mode to System Mode Assignment - Day
Mode
Day Mode = Mode 1~8
1 = default
Night Mode = Mode 1~8
2 = default

Table of Contents

Other manuals for NEC Univerge SV9100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Univerge SV9100 and is the answer not in the manual?

NEC Univerge SV9100 Specifications

General IconGeneral
VoIP SupportYes
VoIP ProtocolsSIP, H.323
VoicemailIntegrated voicemail
NetworkingYes, via IP
Unified CommunicationsYes
MobilitySupports mobile extensions and applications
TypeIP-PBX
Network InterfacesGigabit Ethernet
Power SupplyAC 100-240V, 50/60Hz
Operating Temperature32°F to 104°F (0°C to 40°C)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
WeightVaries depending on chassis and expansion cards

Related product manuals