Issue 2.0
SV9100 Networking Manual 3-5
1.5 Programming for Open Numbering Plan
Use these programs to assign the number of digits to Access Code and to make
ARS assignments.
44-02-03
Dial Analysis Table for
ARS/F-Route Access –
Additional Data
2 = 0 ~ 500
(0 = No Setting)
Default is 0
When setting data is 2, refer to
Program 44-05 for further routing
options.
44-05-01
ARS/F-Route Table –
Trunk Group Number
0-100,101-150,255
0 = Not Set
1~100 = Trunk Group from
14-05
101~150 = Networking
255 = Extension Call
Default is 0
Select the trunk group to be used
for the outgoing K-CCIS call.
Table 3-5 Open Numbering Plan Assignments
Program/
Item No.
Description/
Selection
Assigned Data Comments
11-01-01
System Numbering
2 = Extension Number Default for 1X, 2X, and 3X is 2
44-02-01
Dial Analysis Table for
ARS/F-Route Access –
Number of digits to be
analyzed by the system
Up to eight digits can be
assigned.
Default is No setting
Assign the digits to be dialed
across the K-CCIS link. These
digits were assigned as F-Route
in Program 11-01-01.
Use line key l for “Don’t Care”
digit @.
44-02-02
Dial Analysis Table for
ARS/F-Route Access –
Service Type
2 = ARS/F-Route Table
Default is 0
Service type 2 assigns the digits
to be dialed to an F-Route.
Program 44-02-03 assigns the
F-Route to be used.
44-02-03
Dial Analysis Table for
ARS/F-Route Access –
Additional Data
2 = 0 ~ 500
(0 = No Setting)
Default is 0
When setting data is (2), refer to
Program 44-05.
44-05-01
ARS/F-Route Table –
Trunk Group Number
0-100,101-150,255
0 = Not Set
1~100 = Trunk Group from
14-05
101~150 = Networking
255 = Extension Call
Default is 0
Select the trunk group to be used
for the outgoing K-CCIS call.
Table 3-4 Closed Numbering Plan Assignments (Continued)
Program/
Item No.
Description/
Selection
Assigned Data Comments

Table of Contents

Other manuals for NEC Univerge SV9100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Univerge SV9100 and is the answer not in the manual?

NEC Univerge SV9100 Specifications

General IconGeneral
VoIP SupportYes
VoIP ProtocolsSIP, H.323
VoicemailIntegrated voicemail
NetworkingYes, via IP
Unified CommunicationsYes
MobilitySupports mobile extensions and applications
TypeIP-PBX
Network InterfacesGigabit Ethernet
Power SupplyAC 100-240V, 50/60Hz
Operating Temperature32°F to 104°F (0°C to 40°C)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
WeightVaries depending on chassis and expansion cards

Related product manuals