Issue 2.0
10-38 SV9100 NetLink
Be careful when changing the communication server database. If the Primary
System is changed before synchronization, the edited data is lost.
8.1 Asynchronous Settings
The following program settings are not updated by the Primary System:
10-01, 10-02, 10-12, 10-13, 10-14, 10-15, 10-16, 10-45, 51-01, 90-01, 90-09.
8.2 SRAM Database
Data in SRAM area is not transferred to Secondary Systems. When Fail-Over
occurs, a terminal may lose DND, Caller ID History, etc.
Related Programming:
51-09-06 : NetLink TCP Port Settings – Database Replication Secondary
System Listening Port
Define the listening port used so the Secondary SV9100 can replicate the
Primary SV9100 database (0~65535).
51-09-07 : NetLink TCP Port Settings – Database Replication Primary System
Detection Port
Define the port used for communication so that the Primary SV9100 may
synchronize the Secondary SV9100 with the program data (0~65535). If 0 is
entered, the port is selected dynamically.
51-16-01 : NetLink System Data Replication Mode Setting – System Data
Replication Mode
Set the replication mode (0 = Disabled, 1 = Setting Time Mode, 2 = Interval
Mode). An entry of 1 replicates the data at the time set in Program 51-16-02. If
this option is set to 2, replication occurs at the time set in Program 51-16-03.
51-16-02 : NetLink System Data Replication Mode Setting – System Data
Replication Time Setting
If Program 51-16-01 is set to 1, set the time to replicate the program data
(0000~2359).
51-16-03 : NetLink System Data Replication Mode Setting – System Data
Replication Interval Setting
If Program 51-16-01 is set to 2, set the time between replicating the program
data (15-1440 minutes).
51-16-04 : NetLink System Data Replication Mode Setting – Replication Time
Stamp
This program displays the last time the program data was replicated. This is
automatically updated when the replication occurs. This option is view-only.
51-16-05 : NetLink System Data Replication Mode Setting – System Data
Replication Wait Time
When a NetLink network is created, this option determines the time the SV9100
waits before replication is started (1~86400 seconds).