Issue 2.0
SV9100 Networking Manual 10-25
SECTION 5 NETLINK FUNCTIONS
5.1 Programming
The following programs require a GCD-CP10 reset after making a change via
PCPro, Web Pro and handset programming.
Minimum Required Programming
10-12-09 : GCD-CP10 Network Setup – VoIP Daughter Board IP Address
Set the LAN IP address VoIP daughter board. The IP number increases by one
for each increase in the slot number.
10-12-10 : GCD-CP10 Network Setup – VoIP Daughter Board Subnet Mask
Define the subnet mask for the channel VoIP daughter board. The setting of
Subnet Mask errors when all Host Addresses are 0.
51-01-01 : NetLink System Settings – NetLink System ID
This is the ID number (0 = Disabled, 1-50) that identifies each SV9100 in the
NetLink network. Each SV9100 must have a unique number in the network.
When this option is set to 0, NetLink is disabled.
The SV9100 must be reset when changing this option.
51-03-01 : NetLink Internet Protocol Address List Setting – Internet
Protocol Address List
The communications server sees the Primary SV9100 from in this list. When no
Primary SV9100 is seen or Fail-Over occurs, the Node List is referred to
establish a new link. This setting is necessary when Program 51-01-03 is set to
0 or Program 51-05-02 is other than 0.
Program When Changed via
10-12-01 Handset, Web Pro, PCPro
10-12-02 Handset, Web Pro, PCPro
10-12-09 Handset, Web Pro, PCPro
10-12-10 Handset, Web Pro, PCPro
51-01-01 Handset, Web Pro, PCPro
51-15 Handset, Web Pro
84-03-06 Handset, Web Pro, PCPro
90-04 Handset Programming
90-58 Handset Programming
10-46-07 PCPro
84-23 Handset, Web Pro, PCPro
When Program 90-08-01 System Reset is performed from any site in a NetLink
Network, the Primary System will be reset.