Issue 2.0
SV9100 Networking Manual 3-17
1.9 Shared Tandem CO Trunk Calls
The following diagram provides an example of Programs and item numbers that
should be assigned when two sites share CO lines for reducing Long Distance
calls using Automatic Route Selection (ARS).
The example assumes that the UNIVERGE SV9100 systems are connected via
K-CCIS and using Closed Numbering Plan. All local calls are 10-digit dial and all
1+ calls are 11-digit dial.
MB = Memory Block TRK = Trunk TG = Trunk Group
TB = ARS Table DN = Dial Number RT = ARS Route
PRG 11-01-01 PRG 11-01-01
Dial 9 = 1 digit: Trunk Access Dial 9 = 1 digit: Trunk Access
PRG 11-09-01 PRG 11-09-01
Trunk Access Code = 9 Trunk Access Code = 9
PRG 11-09-02 PRG 11-09-02
2
nd
Trunk Access = 8 2
nd
Trunk Access = 8
PRG 26-01-01 PRG 26-01-01
ARS Service = On ARS Service = On
PRG 26-02-01 PRG 26-02-01
ARS Analysis TBL1 = 1214 ARS Analysis TBL1 = 1817
ARS Analysis TBL2 = 1972 ARS Analysis TBL2 = 1940
ARS Analysis TBL3 = 1817 ARS Analysis TBL3 = 1214
PRG 26-02-02 PRG 26-02-02
ARS Analysis TBL1 = F-Route ARS Analysis TBL1 = F-Route
ARS Analysis TBL2 = F-Route ARS Analysis TBL2 = F-Route
ARS Analysis TBL3 = TRG (Trunk Group) ARS Analysis TBL3 = TRG (Trunk Group)
UNIVERGE
SV9100
Remote
101s 301s
TG10
TG10
CO Trunks
UNIVERGE
SV9100
Main
K-CCIS Link
CO Trunks
Area Code 817
Area Code 940
Area Code 214
Area Code 972

Table of Contents

Other manuals for NEC Univerge SV9100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Univerge SV9100 and is the answer not in the manual?

NEC Univerge SV9100 Specifications

General IconGeneral
VoIP SupportYes
VoIP ProtocolsSIP, H.323
VoicemailIntegrated voicemail
NetworkingYes, via IP
Unified CommunicationsYes
MobilitySupports mobile extensions and applications
TypeIP-PBX
Network InterfacesGigabit Ethernet
Power SupplyAC 100-240V, 50/60Hz
Operating Temperature32°F to 104°F (0°C to 40°C)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
WeightVaries depending on chassis and expansion cards

Related product manuals