EasyManuals Logo

NEC Univerge SV9100 User Manual

NEC Univerge SV9100
766 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #221 background imageLoading...
Page #221 background image
Issue 2.0
5-26 SV9100 IP K-CCIS
2.6 IP K-CCIS Assignment
Use these programs to assign CCIS availability, origination and destination point
codes for IP K-CCIS.
2.7 IP K-CCIS (Peer-to-Peer) Assignment
Use these programs to assign the CCIPS over IP connection method and the TCP
server port number.
Table 5-12 IP K-CCIS Assignments
Program/
Item No.
Description/Selection Assigned Data Comments
50-01-01
CCIS System Setting –
CCIS Availability
0 = Disable
1 = Enable
Default is 0
50-02-03
Connecting System
Settings – Originating
Point Code
0 ~ 16367
Default is 0
Assign the Originating Point
Code for Route ID 9 of own side.
50-03-01
CCIS Destination System
Settings – Destination
Point Code
0 ~ 16367
Default is 0
Assign remote system IP network
information.
PRG 50-03 assignments are only
used only for CCISoIP.
50-03-03
CCIS Destination System
Settings – IP Address (IP
only)
xxx.xxx.xxx.xxx
(xxx = 0 ~ 255)
Default is 0.0.0.0
Assign remote system IP network
information.
PRG 50-03 assignments are only
used for CCISoIP.
50-03-04
CCIS Destination System
Settings – Point Code
Availability
0 : Disable
1 : Enable
Default is 1
Table 5-13 IP K-CCIS (Peer-to-Peer) Assignments
Program/
Item No.
Description/Selection Assigned Data Comments
50-15-02
CCIS over IP Basic
Information Setting –TCP
Server Port Number
0 ~ 65535
Default is 57000
50-15-03
CCIS over IP Basic
Information Setting –
TCP Client Base Port
Number
0 ~ 65535
Default is 59000

Table of Contents

Other manuals for NEC Univerge SV9100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Univerge SV9100 and is the answer not in the manual?

NEC Univerge SV9100 Specifications

General IconGeneral
VoIP SupportYes
VoIP ProtocolsSIP, H.323
VoicemailIntegrated voicemail
NetworkingYes, via IP
Unified CommunicationsYes
MobilitySupports mobile extensions and applications
TypeIP-PBX
Network InterfacesGigabit Ethernet
Power SupplyAC 100-240V, 50/60Hz
Operating Temperature32°F to 104°F (0°C to 40°C)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
WeightVaries depending on chassis and expansion cards

Related product manuals