Chapter 19 Control Panel Setup (Panel)
1141
Overall Control Panel Settings (Config Menu)
Notes
In the auxiliary bus control block and other control blocks which are excluded
from M/E and PGM/PST banks, the operations on the utility 2 bus and keys 1
to 4 are not inhibited.
1
In the Panel >Config menu, press [Operation Inhibit].
Operation Inhibit menu appears.
2
Press [M/E Operation Inhibit].
The M/E Operation Inhibit menu appears.
3
In the list in the status area, using any of the following methods, select the
switcher bank for which operations are to be inhibited.
• Press directly on the desired switcher bank in the list.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
4
In the <M/E Operation Inhibit> group, press the utility 2 bus or key button
([Util2 Bus] or [Key1] to [Key4]) for which operations are to be inhibited.
Inhibiting DME Channel Selection Operations
You can inhibit DME channel selection operations from the device control
block (trackball) or device control block (joystick).
1
In the Panel >Config menu, press [Operation Inhibit].
The Operation Inhibit menu appears.
2
Press [Joystick/Trackball Module].
The Joystick/Trackball Module menu appears.
3
In the list in the status area, using any of the following methods, select the
DME channel for which operations are to be inhibited.
• Press directly on the desired DME channel in the list.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob Parameter Adjustment Setting values
1 Bank Switcher bank selection for
inhibiting operations
1 to 4