Chapter 21 DME Setup (DME)
1257
Settings Relating to Signal Outputs (Output Menu)
Settings Relating to Signal Outputs (Output
Menu)
To make settings relating to DME output signals, display the DME >Output
menu.
To display the Output menu
In the Engineering Setup menu, select VF4 ‘DME’ and HF3 ‘Output.’
These settings are possible only when the DME is an MVE-9000 or SDI-
interfaced MVE-8000A.
The following functions are available here.
• Clip Adjust: Adjust the video clip levels of DME1 and DME2 outputs.
• Monitor Output: Set the signals output from the four monitor output
connectors.
Adjusting the DME1 and DME2 Output Video Clip
Levels
When the MVE-8000A/MVE-9000 is connected through SDI interface, you
can adjust both DME1 and DME2 output video clip levels.
Use the following procedure. (DME 1 is taken by way of example.)
1
In the <DME1(Ch1-Ch4)> group of the DME >Output menu, press [Clip
Adjust], turning it on.
2
Set the following parameters.
To return the setting to the default value
In the DME >Output menu, press [Default].
Knob Parameter Adjustment Setting values
1 White Clip White clip adjustment 90.00 to 109.02
2 Dark Clip Dark clip adjustment −6.85 to +10.00
3 Chroma Clip Chroma clip adjustment 90.00 to 113.17